#1

GET https://tx.fhir.org/r4/metadata HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
User-Agent: fhir/publisher
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4261
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:47:51 GMT
etag:W/"10a5-Q9waoaeUgzoTQHfERlZ1jx4DizY"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378463

{"resourceType":"CapabilityStatement","id":"FhirServer","extension":[{"extension":[{"url":"definition","valueCanonical":"http://hl7.org/fhir/uv/tx-tests/FeatureDefinition/test-version"},{"url":"value","valueCode":"1.9.1"},{"extension":[{"url":"name","valueCode":"mode"},{"url":"value","valueCode":"tx.fhir.org"}],"url":"qualifier"}],"url":"http://hl7.org/fhir/uv/application-feature/StructureDefinition/feature"},{"extension":[{"url":"definition","valueCanonical":"http://hl7.org/fhir/uv/tx-ecosystem/FeatureDefinition/CodeSystemAsParameter"},{"url":"value","valueBoolean":true}],"url":"http://hl7.org/fhir/uv/application-feature/StructureDefinition/feature"}],"url":"https://node.tx.fhir.org/r4/CapabilityStatement/tx","version":"4.0.1-0.9.7","name":"FHIRTerminologyServer","title":"FHIR Terminology Server","status":"active","date":"2026-06-26T06:47:51.891Z","contact":[{"telecom":[{"system":"other","value":"http://example.org/"}]}],"description":"FHIR Terminology Server","kind":"instance","instantiates":["http://hl7.org/fhir/CapabilityStatement/terminology-server"],"software":{"name":"FHIRsmith","version":"0.9.7","releaseDate":"2026-06-26T06:47:51.891Z"},"implementation":{"description":"FHIR Server running at https://node.tx.fhir.org/r4","url":"https://node.tx.fhir.org/r4"},"fhirVersion":"4.0.1","format":["application/fhir+xml","application/fhir+json"],"rest":[{"mode":"server","security":{"cors":true},"resource":[{"type":"CodeSystem","interaction":[{"code":"read","documentation":"Read a code system"},{"code":"search-type","documentation":"Search the code systems"}],"searchParam":[{"name":"url","type":"uri"},{"name":"version","type":"token"},{"name":"name","type":"string"},{"name":"title","type":"string"},{"name":"status","type":"token"},{"name":"_id","type":"token"}],"operation":[{"name":"lookup","definition":"http://hl7.org/fhir/OperationDefinition/CodeSystem-lookup"},{"name":"validate-code","definition":"http://hl7.org/fhir/OperationDefinition/CodeSystem-validate-code"},{"name":"subsumes","definition":"http://hl7.org/fhir/OperationDefinition/CodeSystem-subsumes"}]},{"type":"ValueSet","interaction":[{"code":"read","documentation":"Read a ValueSet"},{"code":"search-type","documentation":"Search the value sets"}],"searchParam":[{"name":"url","type":"uri"},{"name":"version","type":"token"},{"name":"name","type":"string"},{"name":"title","type":"string"},{"name":"status","type":"token"},{"name":"_id","type":"token"}],"operation":[{"name":"expand","definition":"http://hl7.org/fhir/OperationDefinition/ValueSet-expand"},{"name":"validate-code","definition":"http://hl7.org/fhir/OperationDefinition/ValueSet-validate-code"},{"name":"related","definition":"https://raw.githubusercontent.com/HealthIntersections/FHIRsmith/refs/heads/main/tx/data/OperationDefinition-ValueSet-related.json"}]},{"type":"ConceptMap","interaction":[{"code":"read","documentation":"Read a ConceptMap"},{"code":"search-type","documentation":"Search the concept maps"}],"searchParam":[{"name":"url","type":"uri"},{"name":"version","type":"token"},{"name":"name","type":"string"},{"name":"title","type":"string"},{"name":"status","type":"token"},{"name":"_id","type":"token"}],"operation":[{"name":"translate","definition":"http://hl7.org/fhir/OperationDefinition/ConceptMap-translate"},{"name":"closure","definition":"http://hl7.org/fhir/OperationDefinition/ConceptMap-closure"}]}],"interaction":[{"code":"transaction"}],"operation":[{"name":"expand","definition":"http://hl7.org/fhir/OperationDefinition/ValueSet-expand"},{"name":"lookup","definition":"http://hl7.org/fhir/OperationDefinition/CodeSystem-lookup"},{"name":"subsumes","definition":"http://hl7.org/fhir/OperationDefinition/CodeSystem-subsumes"},{"name":"validate-code","definition":"http://hl7.org/fhir/OperationDefinition/Resource-validate-code"},{"name":"translate","definition":"http://hl7.org/fhir/OperationDefinition/ConceptMap-translate"},{"name":"closure","definition":"http://hl7.org/fhir/OperationDefinition/ConceptMap-closure"},{"name":"related","definition":"https://raw.githubusercontent.com/HealthIntersections/FHIRsmith/refs/heads/main/tx/data/OperationDefinition-ValueSet-related.json"},{"name":"versions","definition":"http://hl7.org/fhir/OperationDefinition/fhir-versions"}]}]}

#2

GET https://tx-nordics.fhir.org/fhir/r4/metadata HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
User-Agent: fhir/publisher
200
cache-control:no-cache
content-location:https://tx-nordics.fhir.org/fhir/r4/CapabilityStatement/9fb42271-de2b-46d5-9673-d45912608e6f
content-type:application/fhir+json;charset=UTF-8
date:Fri, 26 Jun 2026 06:48:07 GMT
server:nginx
vary:Origin
vary:Access-Control-Request-Method
vary:Access-Control-Request-Headers
vary:Accept,Origin,Accept-Encoding,Accept-Language,Authorization
x-content-type-options:nosniff
x-correlation-id:6b9d639b-c1cc-4fd0-865b-0f8af818b3b6
x-frame-options:DENY
x-powered-by:HAPI FHIR 8.4.0 REST Server (FHIR Server; FHIR 4.0.1/R4)
x-request-id:6b9d639b-c1cc-4fd0-865b-0f8af818b3b6
x-xss-protection:0

{"resourceType":"CapabilityStatement","id":"9fb42271-de2b-46d5-9673-d45912608e6f","text":{"status":"generated","div":"<div xmlns=\"http://www.w3.org/1999/xhtml\">HAPI FHIR Server</div>"},"extension":[{"url":"http://hl7.org/fhir/uv/application-feature/StructureDefinition/feature","extension":[{"url":"definition","valueCanonical":"http://hl7.org/fhir/uv/tx-tests/FeatureDefinition/test-version"},{"url":"value","valueCode":"1.7.6"},{"url":"qualifier","extension":[{"url":"name","valueCode":"mode"},{"url":"value","valueCode":"ontoserver"},{"url":"value","valueCode":"flat"}]}]},{"url":"http://hl7.org/fhir/uv/application-feature/StructureDefinition/feature","extension":[{"url":"definition","valueCanonical":"http://hl7.org/fhir/uv/tx-ecosystem/FeatureDefinition/CodeSystemAsParameter"},{"url":"value","valueBoolean":true}]}],"url":"https://tx-nordics.fhir.org/fhir/r4/metadata","version":"6.23.0.1782196248356","name":"FHIR_Conformance_statement_for_Ontoserver","title":"FHIR Conformance statement for Ontoserver®","status":"active","experimental":true,"date":"2026-06-23T08:30:45.916+02:00","publisher":"The Australian e-Health Research Centre, CSIRO","contact":[{"telecom":[{"system":"email","value":"ontoserver-support@csiro.au"}]}],"description":"An instance of Ontoserver implementing the HL7 FHIR terminology server specification.","kind":"instance","instantiates":["http://hl7.org/fhir/CapabilityStatement/terminology-server"],"software":{"extension":[{"url":"http://ontoserver.csiro.au/profiles/ontoserver-versions","extension":[{"url":"snomedIndexVersion","valueString":"2.0.15"},{"url":"loincIndexVersion","valueString":"2.0.7"},{"url":"fhirIndexVersion","valueString":"2.8.0"}]}],"name":"Ontoserver®","version":"6.23.0","releaseDate":"2025-09-05T05:29:28+02:00"},"implementation":{"extension":[{"url":"http://ontoserver.csiro.au/profiles/ontoserver-endpoints","extension":[{"url":"api","valueUri":"https://tx-nordics.fhir.org/api"},{"url":"synd","valueUri":"https://tx-nordics.fhir.org/synd"}]}],"description":"Ontoserver, The Australian e-Health Research Centre, CSIRO","url":"https://tx-nordics.fhir.org/fhir/r4"},"fhirVersion":"4.0.1","format":["application/fhir+xml","xml","application/fhir+json","json","application/x-turtle","ttl"],"rest":[{"mode":"server","security":{"cors":true,"service":[{"coding":[{"system":"http://terminology.hl7.org/CodeSystem/restful-security-service","code":"Basic"}],"text":"Basic authentication defined in HTTP specification"}]},"resource":[{"type":"Account","profile":"http://hl7.org/fhir/StructureDefinition/Account","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ActivityDefinition","profile":"http://hl7.org/fhir/StructureDefinition/ActivityDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"AdverseEvent","profile":"http://hl7.org/fhir/StructureDefinition/AdverseEvent","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"AllergyIntolerance","profile":"http://hl7.org/fhir/StructureDefinition/AllergyIntolerance","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Appointment","profile":"http://hl7.org/fhir/StructureDefinition/Appointment","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"AppointmentResponse","profile":"http://hl7.org/fhir/StructureDefinition/AppointmentResponse","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"AuditEvent","profile":"http://hl7.org/fhir/StructureDefinition/AuditEvent","interaction":[{"code":"create"}],"operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Basic","profile":"http://hl7.org/fhir/StructureDefinition/Basic","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Binary","profile":"http://hl7.org/fhir/StructureDefinition/Binary","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"BiologicallyDerivedProduct","profile":"http://hl7.org/fhir/StructureDefinition/BiologicallyDerivedProduct","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"BodyStructure","profile":"http://hl7.org/fhir/StructureDefinition/BodyStructure","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Bundle","profile":"http://hl7.org/fhir/StructureDefinition/Bundle","interaction":[{"code":"search-type"},{"code":"update"},{"code":"vread"},{"code":"read"},{"code":"patch"},{"code":"history-instance"},{"code":"history-type"},{"code":"delete"},{"code":"create"}],"versioning":"versioned-update","readHistory":true,"searchParam":[{"name":"_sort","type":"string"},{"name":"_count","type":"number"},{"name":"_id","type":"string","documentation":"The ID of the resource"},{"name":"_lastUpdated","type":"date","documentation":"Only return resources which were last updated as specified by the given range"},{"name":"_security","type":"token","documentation":"The security of the resource"},{"name":"_tag","type":"token","documentation":"The tag of the resource"},{"name":"identifier","type":"token","documentation":"Persistent identifier for the bundle"},{"name":"type","type":"token","documentation":"document | message | transaction | transaction-response | batch | batch-response | history | searchset | collection"},{"name":"x-syndication-status","type":"token"}],"operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"},{"name":"meta-delete","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-delete"},{"name":"meta-add","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-add"},{"name":"meta","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"}]},{"type":"CapabilityStatement","profile":"http://hl7.org/fhir/StructureDefinition/CapabilityStatement","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CarePlan","profile":"http://hl7.org/fhir/StructureDefinition/CarePlan","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CareTeam","profile":"http://hl7.org/fhir/StructureDefinition/CareTeam","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CatalogEntry","profile":"http://hl7.org/fhir/StructureDefinition/CatalogEntry","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ChargeItem","profile":"http://hl7.org/fhir/StructureDefinition/ChargeItem","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ChargeItemDefinition","profile":"http://hl7.org/fhir/StructureDefinition/ChargeItemDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Claim","profile":"http://hl7.org/fhir/StructureDefinition/Claim","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ClaimResponse","profile":"http://hl7.org/fhir/StructureDefinition/ClaimResponse","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ClinicalImpression","profile":"http://hl7.org/fhir/StructureDefinition/ClinicalImpression","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CodeSystem","profile":"http://hl7.org/fhir/StructureDefinition/CodeSystem","interaction":[{"code":"search-type"},{"code":"update","documentation":"The `CodeSystem.url` cannot equal the well-known code system URLs for SNOMED CT and LOINC if `CodeSystem.content == COMPLETE`. Otherwise, the `CodeSystem.valueSet` URI cannot overlap with the URLs for the implicit ValueSets of SNOMED CT and LOINC."},{"code":"vread"},{"code":"read"},{"code":"patch"},{"code":"history-instance"},{"code":"history-type"},{"code":"delete"},{"code":"create","documentation":"The `CodeSystem.url` cannot equal the well-known code system URLs for SNOMED CT and LOINC if `CodeSystem.content == COMPLETE`. Otherwise, the `CodeSystem.valueSet` URI cannot overlap with the URLs for the implicit ValueSets of SNOMED CT and LOINC."}],"versioning":"versioned-update","readHistory":true,"searchParam":[{"name":"_sort","type":"string"},{"name":"_count","type":"number"},{"name":"_id","type":"string","documentation":"The ID of the resource"},{"name":"_lastUpdated","type":"date","documentation":"Only return resources which were last updated as specified by the given range"},{"name":"_security","type":"token","documentation":"The security of the resource"},{"name":"_tag","type":"token","documentation":"The tag of the resource"},{"name":"content-mode","type":"token","documentation":"not-present | example | fragment | complete | supplement"},{"name":"context","type":"token","documentation":"A use context assigned to the code system"},{"name":"context-type","type":"token","documentation":"A type of use context assigned to the code system"},{"name":"context-type-value","type":"composite","documentation":"A use context type and value assigned to the code system"},{"name":"description","type":"string","documentation":"The description of the code system"},{"name":"identifier","type":"token","documentation":"External identifier for the code system"},{"name":"name","type":"string","documentation":"Computationally friendly name of the code system"},{"name":"publisher","type":"string","documentation":"Name of the publisher of the code system"},{"name":"status","type":"token","documentation":"The current status of the code system"},{"name":"system","type":"uri","documentation":"The system for any codes defined by this code system (same as 'url')"},{"name":"title","type":"string","documentation":"The human-friendly name of the code system"},{"name":"url","type":"uri","documentation":"The uri that identifies the code system"},{"name":"version","type":"token","documentation":"The business version of the code system"},{"name":"x-syndication-status","type":"token"}],"operation":[{"name":"validate-code","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/CodeSystemValueSet-it-validate-code"},{"name":"subsumes","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/CodeSystem-it-subsumes"},{"name":"lookup","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/CodeSystem-t-lookup"},{"name":"find-matches","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/CodeSystem-it-find-matches"},{"name":"x-upload-external","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/CodeSystem-t-x-upload-external","documentation":"SNOMED CT and LOINC can also be loaded by directly POSTing a ZIP file to this operation."},{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"},{"name":"meta-delete","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-delete"},{"name":"meta-add","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-add"},{"name":"meta","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"}]},{"type":"Communication","profile":"http://hl7.org/fhir/StructureDefinition/Communication","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CommunicationRequest","profile":"http://hl7.org/fhir/StructureDefinition/CommunicationRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CompartmentDefinition","profile":"http://hl7.org/fhir/StructureDefinition/CompartmentDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Composition","profile":"http://hl7.org/fhir/StructureDefinition/Composition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ConceptMap","profile":"http://hl7.org/fhir/StructureDefinition/ConceptMap","interaction":[{"code":"search-type"},{"code":"update","documentation":"The `ConceptMap.url` cannot overlap with the URLs for the implicit ConceptMaps of SNOMED CT and LOINC."},{"code":"vread"},{"code":"read"},{"code":"patch"},{"code":"history-instance"},{"code":"history-type"},{"code":"delete"},{"code":"create","documentation":"The `ConceptMap.url` cannot overlap with the URLs for the implicit ConceptMaps of SNOMED CT and LOINC."}],"versioning":"versioned-update","readHistory":true,"searchParam":[{"name":"_sort","type":"string"},{"name":"_count","type":"number"},{"name":"_id","type":"string","documentation":"The ID of the resource"},{"name":"_lastUpdated","type":"date","documentation":"Only return resources which were last updated as specified by the given range"},{"name":"_security","type":"token","documentation":"The security of the resource"},{"name":"_tag","type":"token","documentation":"The tag of the resource"},{"name":"context","type":"token","documentation":"A use context assigned to the concept map"},{"name":"context-type","type":"token","documentation":"A type of use context assigned to the concept map"},{"name":"context-type-value","type":"composite","documentation":"A use context type and value assigned to the concept map"},{"name":"description","type":"string","documentation":"The description of the concept map"},{"name":"identifier","type":"token","documentation":"External identifier for the concept map"},{"name":"name","type":"string","documentation":"Computationally friendly name of the concept map"},{"name":"publisher","type":"string","documentation":"Name of the publisher of the concept map"},{"name":"source-code","type":"token","documentation":"Identifies element being mapped"},{"name":"source-system","type":"uri","documentation":"Source system where concepts to be mapped are defined"},{"name":"source-uri","type":"token","documentation":"The source value set that contains the concepts that are being mapped"},{"name":"status","type":"token","documentation":"The current status of the concept map"},{"name":"target-code","type":"token","documentation":"Code that identifies the target element"},{"name":"target-system","type":"uri","documentation":"Target system that the concepts are to be mapped to"},{"name":"target-uri","type":"token","documentation":"The target value set which provides context for the mappings"},{"name":"title","type":"string","documentation":"The human-friendly name of the concept map"},{"name":"url","type":"uri","documentation":"The uri that identifies the concept map"},{"name":"version","type":"token","documentation":"The business version of the concept map"},{"name":"x-syndication-status","type":"token"}],"operation":[{"name":"translate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/ConceptMap-it-translate"},{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"},{"name":"meta-delete","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-delete"},{"name":"meta-add","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-add"},{"name":"meta","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"}]},{"type":"Condition","profile":"http://hl7.org/fhir/StructureDefinition/Condition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Consent","profile":"http://hl7.org/fhir/StructureDefinition/Consent","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Contract","profile":"http://hl7.org/fhir/StructureDefinition/Contract","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Coverage","profile":"http://hl7.org/fhir/StructureDefinition/Coverage","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CoverageEligibilityRequest","profile":"http://hl7.org/fhir/StructureDefinition/CoverageEligibilityRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"CoverageEligibilityResponse","profile":"http://hl7.org/fhir/StructureDefinition/CoverageEligibilityResponse","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DetectedIssue","profile":"http://hl7.org/fhir/StructureDefinition/DetectedIssue","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Device","profile":"http://hl7.org/fhir/StructureDefinition/Device","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DeviceDefinition","profile":"http://hl7.org/fhir/StructureDefinition/DeviceDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DeviceMetric","profile":"http://hl7.org/fhir/StructureDefinition/DeviceMetric","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DeviceRequest","profile":"http://hl7.org/fhir/StructureDefinition/DeviceRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DeviceUseStatement","profile":"http://hl7.org/fhir/StructureDefinition/DeviceUseStatement","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DiagnosticReport","profile":"http://hl7.org/fhir/StructureDefinition/DiagnosticReport","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DocumentManifest","profile":"http://hl7.org/fhir/StructureDefinition/DocumentManifest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"DocumentReference","profile":"http://hl7.org/fhir/StructureDefinition/DocumentReference","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"EffectEvidenceSynthesis","profile":"http://hl7.org/fhir/StructureDefinition/EffectEvidenceSynthesis","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Encounter","profile":"http://hl7.org/fhir/StructureDefinition/Encounter","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Endpoint","profile":"http://hl7.org/fhir/StructureDefinition/Endpoint","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"EnrollmentRequest","profile":"http://hl7.org/fhir/StructureDefinition/EnrollmentRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"EnrollmentResponse","profile":"http://hl7.org/fhir/StructureDefinition/EnrollmentResponse","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"EpisodeOfCare","profile":"http://hl7.org/fhir/StructureDefinition/EpisodeOfCare","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"EventDefinition","profile":"http://hl7.org/fhir/StructureDefinition/EventDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Evidence","profile":"http://hl7.org/fhir/StructureDefinition/Evidence","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"EvidenceVariable","profile":"http://hl7.org/fhir/StructureDefinition/EvidenceVariable","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ExampleScenario","profile":"http://hl7.org/fhir/StructureDefinition/ExampleScenario","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ExplanationOfBenefit","profile":"http://hl7.org/fhir/StructureDefinition/ExplanationOfBenefit","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"FamilyMemberHistory","profile":"http://hl7.org/fhir/StructureDefinition/FamilyMemberHistory","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Flag","profile":"http://hl7.org/fhir/StructureDefinition/Flag","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Goal","profile":"http://hl7.org/fhir/StructureDefinition/Goal","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"GraphDefinition","profile":"http://hl7.org/fhir/StructureDefinition/GraphDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Group","profile":"http://hl7.org/fhir/StructureDefinition/Group","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"GuidanceResponse","profile":"http://hl7.org/fhir/StructureDefinition/GuidanceResponse","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"HealthcareService","profile":"http://hl7.org/fhir/StructureDefinition/HealthcareService","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ImagingStudy","profile":"http://hl7.org/fhir/StructureDefinition/ImagingStudy","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Immunization","profile":"http://hl7.org/fhir/StructureDefinition/Immunization","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ImmunizationEvaluation","profile":"http://hl7.org/fhir/StructureDefinition/ImmunizationEvaluation","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ImmunizationRecommendation","profile":"http://hl7.org/fhir/StructureDefinition/ImmunizationRecommendation","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ImplementationGuide","profile":"http://hl7.org/fhir/StructureDefinition/ImplementationGuide","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"InsurancePlan","profile":"http://hl7.org/fhir/StructureDefinition/InsurancePlan","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Invoice","profile":"http://hl7.org/fhir/StructureDefinition/Invoice","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Library","profile":"http://hl7.org/fhir/StructureDefinition/Library","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Linkage","profile":"http://hl7.org/fhir/StructureDefinition/Linkage","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"List","profile":"http://hl7.org/fhir/StructureDefinition/List","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Location","profile":"http://hl7.org/fhir/StructureDefinition/Location","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Measure","profile":"http://hl7.org/fhir/StructureDefinition/Measure","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MeasureReport","profile":"http://hl7.org/fhir/StructureDefinition/MeasureReport","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Media","profile":"http://hl7.org/fhir/StructureDefinition/Media","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Medication","profile":"http://hl7.org/fhir/StructureDefinition/Medication","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicationAdministration","profile":"http://hl7.org/fhir/StructureDefinition/MedicationAdministration","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicationDispense","profile":"http://hl7.org/fhir/StructureDefinition/MedicationDispense","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicationKnowledge","profile":"http://hl7.org/fhir/StructureDefinition/MedicationKnowledge","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicationRequest","profile":"http://hl7.org/fhir/StructureDefinition/MedicationRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicationStatement","profile":"http://hl7.org/fhir/StructureDefinition/MedicationStatement","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProduct","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProduct","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductAuthorization","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductAuthorization","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductContraindication","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductContraindication","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductIndication","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductIndication","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductIngredient","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductIngredient","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductInteraction","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductInteraction","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductManufactured","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductManufactured","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductPackaged","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductPackaged","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductPharmaceutical","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductPharmaceutical","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MedicinalProductUndesirableEffect","profile":"http://hl7.org/fhir/StructureDefinition/MedicinalProductUndesirableEffect","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MessageDefinition","profile":"http://hl7.org/fhir/StructureDefinition/MessageDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MessageHeader","profile":"http://hl7.org/fhir/StructureDefinition/MessageHeader","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"MolecularSequence","profile":"http://hl7.org/fhir/StructureDefinition/MolecularSequence","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"NamingSystem","profile":"http://hl7.org/fhir/StructureDefinition/NamingSystem","interaction":[{"code":"search-type"},{"code":"update"},{"code":"vread"},{"code":"read"},{"code":"patch"},{"code":"history-instance"},{"code":"history-type"},{"code":"delete"},{"code":"create"}],"versioning":"versioned-update","readHistory":true,"searchParam":[{"name":"_sort","type":"string"},{"name":"_count","type":"number"},{"name":"_id","type":"string","documentation":"The ID of the resource"},{"name":"_lastUpdated","type":"date","documentation":"Only return resources which were last updated as specified by the given range"},{"name":"_security","type":"token","documentation":"The security of the resource"},{"name":"_tag","type":"token","documentation":"The tag of the resource"},{"name":"context","type":"token","documentation":"A use context assigned to the naming system"},{"name":"context-type","type":"token","documentation":"A type of use context assigned to the naming system"},{"name":"context-type-value","type":"composite","documentation":"A use context type and value assigned to the naming system"},{"name":"description","type":"string","documentation":"The description of the naming system"},{"name":"id-type","type":"token","documentation":"oid | uuid | uri | other"},{"name":"kind","type":"token","documentation":"codesystem | identifier | root"},{"name":"name","type":"string","documentation":"Computationally friendly name of the naming system"},{"name":"publisher","type":"string","documentation":"Name of the publisher of the naming system"},{"name":"status","type":"token","documentation":"The current status of the naming system"},{"name":"value","type":"string","documentation":"The unique identifier"},{"name":"x-syndication-status","type":"token"}],"operation":[{"name":"preferred-id","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/NamingSystem-t-preferred-id"},{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"},{"name":"meta-delete","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-delete"},{"name":"meta-add","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-add"},{"name":"meta","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"}]},{"type":"NutritionOrder","profile":"http://hl7.org/fhir/StructureDefinition/NutritionOrder","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Observation","profile":"http://hl7.org/fhir/StructureDefinition/Observation","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ObservationDefinition","profile":"http://hl7.org/fhir/StructureDefinition/ObservationDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"OperationDefinition","profile":"http://hl7.org/fhir/StructureDefinition/OperationDefinition","interaction":[{"code":"read"}],"operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"OperationOutcome","profile":"http://hl7.org/fhir/StructureDefinition/OperationOutcome","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Organization","profile":"http://hl7.org/fhir/StructureDefinition/Organization","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"OrganizationAffiliation","profile":"http://hl7.org/fhir/StructureDefinition/OrganizationAffiliation","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Parameters","profile":"http://hl7.org/fhir/StructureDefinition/Parameters","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Patient","profile":"http://hl7.org/fhir/StructureDefinition/Patient","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"PaymentNotice","profile":"http://hl7.org/fhir/StructureDefinition/PaymentNotice","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"PaymentReconciliation","profile":"http://hl7.org/fhir/StructureDefinition/PaymentReconciliation","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Person","profile":"http://hl7.org/fhir/StructureDefinition/Person","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"PlanDefinition","profile":"http://hl7.org/fhir/StructureDefinition/PlanDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Practitioner","profile":"http://hl7.org/fhir/StructureDefinition/Practitioner","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"PractitionerRole","profile":"http://hl7.org/fhir/StructureDefinition/PractitionerRole","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Procedure","profile":"http://hl7.org/fhir/StructureDefinition/Procedure","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Provenance","profile":"http://hl7.org/fhir/StructureDefinition/Provenance","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Questionnaire","profile":"http://hl7.org/fhir/StructureDefinition/Questionnaire","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"QuestionnaireResponse","profile":"http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"RelatedPerson","profile":"http://hl7.org/fhir/StructureDefinition/RelatedPerson","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"RequestGroup","profile":"http://hl7.org/fhir/StructureDefinition/RequestGroup","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ResearchDefinition","profile":"http://hl7.org/fhir/StructureDefinition/ResearchDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ResearchElementDefinition","profile":"http://hl7.org/fhir/StructureDefinition/ResearchElementDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ResearchStudy","profile":"http://hl7.org/fhir/StructureDefinition/ResearchStudy","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ResearchSubject","profile":"http://hl7.org/fhir/StructureDefinition/ResearchSubject","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"RiskAssessment","profile":"http://hl7.org/fhir/StructureDefinition/RiskAssessment","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"RiskEvidenceSynthesis","profile":"http://hl7.org/fhir/StructureDefinition/RiskEvidenceSynthesis","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Schedule","profile":"http://hl7.org/fhir/StructureDefinition/Schedule","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SearchParameter","profile":"http://hl7.org/fhir/StructureDefinition/SearchParameter","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ServiceRequest","profile":"http://hl7.org/fhir/StructureDefinition/ServiceRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Slot","profile":"http://hl7.org/fhir/StructureDefinition/Slot","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Specimen","profile":"http://hl7.org/fhir/StructureDefinition/Specimen","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SpecimenDefinition","profile":"http://hl7.org/fhir/StructureDefinition/SpecimenDefinition","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"StructureDefinition","profile":"http://hl7.org/fhir/StructureDefinition/StructureDefinition","interaction":[{"code":"search-type"},{"code":"update"},{"code":"vread"},{"code":"read"},{"code":"patch"},{"code":"history-instance"},{"code":"history-type"},{"code":"delete"},{"code":"create"}],"versioning":"versioned-update","readHistory":true,"searchParam":[{"name":"_sort","type":"string"},{"name":"_count","type":"number"},{"name":"_id","type":"string","documentation":"The ID of the resource"},{"name":"_lastUpdated","type":"date","documentation":"Only return resources which were last updated as specified by the given range"},{"name":"_security","type":"token","documentation":"The security of the resource"},{"name":"_tag","type":"token","documentation":"The tag of the resource"},{"name":"context","type":"token","documentation":"A use context assigned to the structure definition"},{"name":"context-type","type":"token","documentation":"A type of use context assigned to the structure definition"},{"name":"context-type-value","type":"composite","documentation":"A use context type and value assigned to the structure definition"},{"name":"description","type":"string","documentation":"The description of the structure definition"},{"name":"identifier","type":"token","documentation":"External identifier for the structure definition"},{"name":"kind","type":"token","documentation":"primitive-type | complex-type | resource | logical"},{"name":"name","type":"string","documentation":"Computationally friendly name of the structure definition"},{"name":"publisher","type":"string","documentation":"Name of the publisher of the structure definition"},{"name":"status","type":"token","documentation":"The current status of the structure definition"},{"name":"title","type":"string","documentation":"The human-friendly name of the structure definition"},{"name":"type","type":"token","documentation":"Type defined or constrained by this structure"},{"name":"url","type":"uri","documentation":"The uri that identifies the structure definition"},{"name":"version","type":"token","documentation":"The business version of the structure definition"},{"name":"x-syndication-status","type":"token"}],"operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"},{"name":"meta-delete","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-delete"},{"name":"meta-add","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-add"},{"name":"meta","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"}]},{"type":"StructureMap","profile":"http://hl7.org/fhir/StructureDefinition/StructureMap","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Subscription","profile":"http://hl7.org/fhir/StructureDefinition/Subscription","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Substance","profile":"http://hl7.org/fhir/StructureDefinition/Substance","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SubstanceNucleicAcid","profile":"http://hl7.org/fhir/StructureDefinition/SubstanceNucleicAcid","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SubstancePolymer","profile":"http://hl7.org/fhir/StructureDefinition/SubstancePolymer","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SubstanceProtein","profile":"http://hl7.org/fhir/StructureDefinition/SubstanceProtein","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SubstanceReferenceInformation","profile":"http://hl7.org/fhir/StructureDefinition/SubstanceReferenceInformation","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SubstanceSourceMaterial","profile":"http://hl7.org/fhir/StructureDefinition/SubstanceSourceMaterial","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SubstanceSpecification","profile":"http://hl7.org/fhir/StructureDefinition/SubstanceSpecification","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SupplyDelivery","profile":"http://hl7.org/fhir/StructureDefinition/SupplyDelivery","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"SupplyRequest","profile":"http://hl7.org/fhir/StructureDefinition/SupplyRequest","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"Task","profile":"http://hl7.org/fhir/StructureDefinition/Task","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"TerminologyCapabilities","profile":"http://hl7.org/fhir/StructureDefinition/TerminologyCapabilities","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"TestReport","profile":"http://hl7.org/fhir/StructureDefinition/TestReport","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"TestScript","profile":"http://hl7.org/fhir/StructureDefinition/TestScript","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"ValueSet","profile":"http://hl7.org/fhir/StructureDefinition/ValueSet","interaction":[{"code":"search-type"},{"code":"update","documentation":"The `ValueSet.url` cannot overlap with the URLs for the implicit ValueSets of SNOMED CT and LOINC."},{"code":"vread"},{"code":"read"},{"code":"patch"},{"code":"history-instance"},{"code":"history-type"},{"code":"delete"},{"code":"create","documentation":"The `ValueSet.url` cannot overlap with the URLs for the implicit ValueSets of SNOMED CT and LOINC."}],"versioning":"versioned-update","readHistory":true,"searchParam":[{"name":"_sort","type":"string"},{"name":"_count","type":"number"},{"name":"_id","type":"string","documentation":"The ID of the resource"},{"name":"_lastUpdated","type":"date","documentation":"Only return resources which were last updated as specified by the given range"},{"name":"_security","type":"token","documentation":"The security of the resource"},{"name":"_tag","type":"token","documentation":"The tag of the resource"},{"name":"context","type":"token","documentation":"A use context assigned to the value set"},{"name":"context-type","type":"token","documentation":"A type of use context assigned to the value set"},{"name":"context-type-value","type":"composite","documentation":"A use context type and value assigned to the value set"},{"name":"description","type":"string","documentation":"The description of the value set"},{"name":"identifier","type":"token","documentation":"External identifier for the value set"},{"name":"name","type":"string","documentation":"Computationally friendly name of the value set"},{"name":"publisher","type":"string","documentation":"Name of the publisher of the value set"},{"name":"reference","type":"uri","documentation":"A code system included or excluded in the value set or an imported value set"},{"name":"status","type":"token","documentation":"The current status of the value set"},{"name":"title","type":"string","documentation":"The human-friendly name of the value set"},{"name":"url","type":"uri","documentation":"The uri that identifies the value set"},{"name":"version","type":"token","documentation":"The business version of the value set"},{"name":"x-syndication-status","type":"token"}],"operation":[{"name":"validate-code","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/CodeSystemValueSet-it-validate-code"},{"name":"expand","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/ValueSet-it-expand"},{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"},{"name":"meta-delete","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-delete"},{"name":"meta-add","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta-add"},{"name":"meta","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-i-meta"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"}]},{"type":"VerificationResult","profile":"http://hl7.org/fhir/StructureDefinition/VerificationResult","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]},{"type":"VisionPrescription","profile":"http://hl7.org/fhir/StructureDefinition/VisionPrescription","operation":[{"name":"validate","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-it-validate"}]}],"interaction":[{"code":"batch"}],"operation":[{"name":"convert","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/-s-convert"},{"name":"versions","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/-s-versions"},{"name":"diff","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/Multi-is-diff"},{"name":"closure","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/-s-closure"},{"name":"x-load-package","definition":"https://tx-nordics.fhir.org/fhir/r4/OperationDefinition/-s-x-load-package","documentation":"The Ontoserver-compatible contents of a FHIR Package posted to this endpoint will be loaded."}]}]}

#3

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4270
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:25 GMT
etag:W/"10ae-vY/dBBejZQrLjW9PIRxHQtPyodE"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378661

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8480-6"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Systolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4471000202106 ('Systolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8480-6 (\"Systolic blood pressure\"), http://snomed.info/sct#4471000202106 (\"Systolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8480-6\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8480-6\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4471000202106\""}]}

#4

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4270
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:25 GMT
etag:W/"10ae-zwnvwZKFw1uQWthdoQk89aXrnfY"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378663

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8480-6"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Systolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4471000202106 ('Systolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8480-6 (\"Systolic blood pressure\"), http://snomed.info/sct#4471000202106 (\"Systolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8480-6\"\n4ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n4ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n4ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8480-6\" found in http://loinc.org|2.82\n4ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4471000202106\""}]}

#5

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4278
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:25 GMT
etag:W/"10b6-LpGN9JlaXZWKde7lga4/jMwL4RA"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378667

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8462-4"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Diastolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4481000202108 ('Diastolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8462-4 (\"Diastolic blood pressure\"), http://snomed.info/sct#4481000202108 (\"Diastolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8462-4\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8462-4\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4481000202108\""}]}

#6

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4278
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:25 GMT
etag:W/"10b6-LpGN9JlaXZWKde7lga4/jMwL4RA"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378669

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8462-4"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Diastolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4481000202108 ('Diastolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8462-4 (\"Diastolic blood pressure\"), http://snomed.info/sct#4481000202108 (\"Diastolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8462-4\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8462-4\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4481000202108\""}]}

#7

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8478-0","display":"Mean blood pressure"},{"system":"http://snomed.info/sct","code":"4501000202102","display":"Mean arterial pressure (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4307
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:26 GMT
etag:W/"10d3-SsLJEDubxXpgO5hwS53hxAgBy9U"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378672

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8478-0"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Mean blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8478-0 for language(s) 'no-NO'. The display is 'Mean blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8478-0","display":"Mean blood pressure"},{"system":"http://snomed.info/sct","code":"4501000202102","display":"Mean arterial pressure (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8478-0 for language(s) 'no-NO'. The display is 'Mean blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4501000202102 ('Mean arterial pressure (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8478-0 (\"Mean blood pressure\"), http://snomed.info/sct#4501000202102 (\"Mean arterial pressure (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8478-0\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8478-0\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4501000202102\""}]}

#8

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8478-0","display":"Mean blood pressure"},{"system":"http://snomed.info/sct","code":"4501000202102","display":"Mean arterial pressure (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4307
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:26 GMT
etag:W/"10d3-6weJPn8BxgnCIR40TZmxhkssnfY"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378674

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8478-0"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Mean blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8478-0 for language(s) 'no-NO'. The display is 'Mean blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8478-0","display":"Mean blood pressure"},{"system":"http://snomed.info/sct","code":"4501000202102","display":"Mean arterial pressure (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8478-0 for language(s) 'no-NO'. The display is 'Mean blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4501000202102 ('Mean arterial pressure (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8478-0 (\"Mean blood pressure\"), http://snomed.info/sct#4501000202102 (\"Mean arterial pressure (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8478-0\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8478-0\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4501000202102\""}]}

#9

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4270
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:26 GMT
etag:W/"10ae-C+QxO6hTOiHrZisfCNC0nk0dS4M"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378676

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8480-6"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Systolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4471000202106 ('Systolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8480-6 (\"Systolic blood pressure\"), http://snomed.info/sct#4471000202106 (\"Systolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8480-6\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8480-6\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4471000202106\""}]}

#10

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4270
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:26 GMT
etag:W/"10ae-vY/dBBejZQrLjW9PIRxHQtPyodE"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378677

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8480-6"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Systolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8480-6","display":"Systolic blood pressure"},{"system":"http://snomed.info/sct","code":"4471000202106","display":"Systolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8480-6 for language(s) 'no-NO'. The display is 'Systolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4471000202106 ('Systolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8480-6 (\"Systolic blood pressure\"), http://snomed.info/sct#4471000202106 (\"Systolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8480-6\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8480-6\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4471000202106\""}]}

#11

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4278
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:27 GMT
etag:W/"10b6-+R84+l7kLm50tZNiayEztnbuWkw"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378678

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8462-4"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Diastolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4481000202108 ('Diastolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8462-4 (\"Diastolic blood pressure\"), http://snomed.info/sct#4481000202108 (\"Diastolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8462-4\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8462-4\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4481000202108\""}]}

#12

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4278
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:27 GMT
etag:W/"10b6-+R84+l7kLm50tZNiayEztnbuWkw"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378680

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8462-4"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Diastolic blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8462-4","display":"Diastolic blood pressure"},{"system":"http://snomed.info/sct","code":"4481000202108","display":"Diastolic blood pressure"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8462-4 for language(s) 'no-NO'. The display is 'Diastolic blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4481000202108 ('Diastolic blood pressure')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8462-4 (\"Diastolic blood pressure\"), http://snomed.info/sct#4481000202108 (\"Diastolic blood pressure\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8462-4\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8462-4\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4481000202108\""}]}

#13

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8478-0","display":"Mean blood pressure"},{"system":"http://snomed.info/sct","code":"4501000202102","display":"Mean arterial pressure (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4307
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:27 GMT
etag:W/"10d3-daL5sgITsoTFVNVfLTxPUWxAAcg"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378682

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8478-0"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Mean blood pressure"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8478-0 for language(s) 'no-NO'. The display is 'Mean blood pressure' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8478-0","display":"Mean blood pressure"},{"system":"http://snomed.info/sct","code":"4501000202102","display":"Mean arterial pressure (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8478-0 for language(s) 'no-NO'. The display is 'Mean blood pressure' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#4501000202102 ('Mean arterial pressure (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8478-0 (\"Mean blood pressure\"), http://snomed.info/sct#4501000202102 (\"Mean arterial pressure (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8478-0\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8478-0\" found in http://loinc.org|2.82\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#4501000202102\""}]}

#14

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8302-2","display":"Body height"},{"system":"http://snomed.info/sct","code":"1153637007","display":"Body height"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4162
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:27 GMT
etag:W/"1042-Gknl7mNjIwpHlTJu3bmLUuegzhE"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378683

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8302-2"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Body height"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8302-2 for language(s) 'no-NO'. The display is 'Body height' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8302-2","display":"Body height"},{"system":"http://snomed.info/sct","code":"1153637007","display":"Body height"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8302-2 for language(s) 'no-NO'. The display is 'Body height' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#1153637007 ('Body height')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8302-2 (\"Body height\"), http://snomed.info/sct#1153637007 (\"Body height\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8302-2\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8302-2\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#1153637007\""}]}

#15

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8302-2","display":"Body height"},{"system":"http://snomed.info/sct","code":"1153637007","display":"Body height"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4162
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:28 GMT
etag:W/"1042-ZfLMFTP/QdShQNG4c7RzWUuzW/U"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378686

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8302-2"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Body height"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8302-2 for language(s) 'no-NO'. The display is 'Body height' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8302-2","display":"Body height"},{"system":"http://snomed.info/sct","code":"1153637007","display":"Body height"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8302-2 for language(s) 'no-NO'. The display is 'Body height' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#1153637007 ('Body height')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8302-2 (\"Body height\"), http://snomed.info/sct#1153637007 (\"Body height\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8302-2\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8302-2\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#1153637007\""}]}

#16

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8310-5","display":"Body temperature"},{"system":"http://snomed.info/sct","code":"276885007","display":"Core body temperature (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4273
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:28 GMT
etag:W/"10b1-lrYKzP++I5VhBmTDRM9YsTABcOc"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378687

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8310-5"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Body temperature"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8310-5 for language(s) 'no-NO'. The display is 'Body temperature' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8310-5","display":"Body temperature"},{"system":"http://snomed.info/sct","code":"276885007","display":"Core body temperature (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8310-5 for language(s) 'no-NO'. The display is 'Body temperature' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#276885007 ('Core body temperature (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8310-5 (\"Body temperature\"), http://snomed.info/sct#276885007 (\"Core body temperature (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8310-5\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8310-5\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#276885007\""}]}

#17

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8310-5","display":"Body temperature"},{"system":"http://snomed.info/sct","code":"276885007","display":"Core body temperature (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4273
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:28 GMT
etag:W/"10b1-lrYKzP++I5VhBmTDRM9YsTABcOc"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378688

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8310-5"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Body temperature"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8310-5 for language(s) 'no-NO'. The display is 'Body temperature' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8310-5","display":"Body temperature"},{"system":"http://snomed.info/sct","code":"276885007","display":"Core body temperature (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8310-5 for language(s) 'no-NO'. The display is 'Body temperature' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#276885007 ('Core body temperature (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8310-5 (\"Body temperature\"), http://snomed.info/sct#276885007 (\"Core body temperature (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8310-5\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8310-5\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#276885007\""}]}

#18

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"29463-7","display":"Body weight"},{"system":"http://snomed.info/sct","code":"27113001","display":"Body weight (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4221
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:28 GMT
etag:W/"107d-B5d8CqAB4Ajn/+gX8Bbofw4QOZI"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378689

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"29463-7"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Body weight"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#29463-7 for language(s) 'no-NO'. The display is 'Body weight' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"29463-7","display":"Body weight"},{"system":"http://snomed.info/sct","code":"27113001","display":"Body weight (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#29463-7 for language(s) 'no-NO'. The display is 'Body weight' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#27113001 ('Body weight (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#29463-7 (\"Body weight\"), http://snomed.info/sct#27113001 (\"Body weight (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#29463-7\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"29463-7\" found in http://loinc.org|2.82\n4ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#27113001\""}]}

#19

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"29463-7","display":"Body weight"},{"system":"http://snomed.info/sct","code":"27113001","display":"Body weight (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4221
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:29 GMT
etag:W/"107d-ydYOyR3muSYxsUQ1vLRh1Mq3xvA"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378691

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"29463-7"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Body weight"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#29463-7 for language(s) 'no-NO'. The display is 'Body weight' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"29463-7","display":"Body weight"},{"system":"http://snomed.info/sct","code":"27113001","display":"Body weight (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#29463-7 for language(s) 'no-NO'. The display is 'Body weight' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#27113001 ('Body weight (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#29463-7 (\"Body weight\"), http://snomed.info/sct#27113001 (\"Body weight (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#29463-7\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"29463-7\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#27113001\""}]}

#20

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8867-4","display":"Heart rate"},{"system":"http://snomed.info/sct","code":"364075005","display":"Heart rate (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4210
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:29 GMT
etag:W/"1072-4RkLuJ09rOv+ouas9AVbob7L/xE"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378692

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8867-4"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Heart rate"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8867-4 for language(s) 'no-NO'. The display is 'Heart rate' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8867-4","display":"Heart rate"},{"system":"http://snomed.info/sct","code":"364075005","display":"Heart rate (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8867-4 for language(s) 'no-NO'. The display is 'Heart rate' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#364075005 ('Heart rate (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8867-4 (\"Heart rate\"), http://snomed.info/sct#364075005 (\"Heart rate (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8867-4\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8867-4\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#364075005\""}]}

#21

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8867-4","display":"Heart rate"},{"system":"http://snomed.info/sct","code":"364075005","display":"Heart rate (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4210
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:29 GMT
etag:W/"1072-4RkLuJ09rOv+ouas9AVbob7L/xE"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378693

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"8867-4"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Heart rate"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#8867-4 for language(s) 'no-NO'. The display is 'Heart rate' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"8867-4","display":"Heart rate"},{"system":"http://snomed.info/sct","code":"364075005","display":"Heart rate (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#8867-4 for language(s) 'no-NO'. The display is 'Heart rate' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#364075005 ('Heart rate (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#8867-4 (\"Heart rate\"), http://snomed.info/sct#364075005 (\"Heart rate (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#8867-4\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"8867-4\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#364075005\""}]}

#22

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"2708-6","display":"Oxygen saturation in Arterial blood"},{"system":"http://snomed.info/sct","code":"431314004","display":"Peripheral oxygen saturation (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4389
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:30 GMT
etag:W/"1125-NIhl5rJbOn7Q701RRMTwEqhBlJ4"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378694

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"2708-6"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Oxygen saturation in Arterial blood"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#2708-6 for language(s) 'no-NO'. The display is 'Oxygen saturation in Arterial blood' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"2708-6","display":"Oxygen saturation in Arterial blood"},{"system":"http://snomed.info/sct","code":"431314004","display":"Peripheral oxygen saturation (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#2708-6 for language(s) 'no-NO'. The display is 'Oxygen saturation in Arterial blood' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#431314004 ('Peripheral oxygen saturation (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#2708-6 (\"Oxygen saturation in Arterial blood\"), http://snomed.info/sct#431314004 (\"Peripheral oxygen saturation (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#2708-6\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"2708-6\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#431314004\""}]}

#23

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"2708-6","display":"Oxygen saturation in Arterial blood"},{"system":"http://snomed.info/sct","code":"431314004","display":"Peripheral oxygen saturation (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4389
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:30 GMT
etag:W/"1125-NIhl5rJbOn7Q701RRMTwEqhBlJ4"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378695

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"2708-6"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Oxygen saturation in Arterial blood"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#2708-6 for language(s) 'no-NO'. The display is 'Oxygen saturation in Arterial blood' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"2708-6","display":"Oxygen saturation in Arterial blood"},{"system":"http://snomed.info/sct","code":"431314004","display":"Peripheral oxygen saturation (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#2708-6 for language(s) 'no-NO'. The display is 'Oxygen saturation in Arterial blood' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#431314004 ('Peripheral oxygen saturation (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#2708-6 (\"Oxygen saturation in Arterial blood\"), http://snomed.info/sct#431314004 (\"Peripheral oxygen saturation (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#2708-6\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"2708-6\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#431314004\""}]}

#24

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"9279-1","display":"Respiratory rate"},{"system":"http://snomed.info/sct","code":"271625008","display":"Rate of spontaneous respiration (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4303
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:30 GMT
etag:W/"10cf-GsfXWlZAivGnfwesQ0g8tWUFYLI"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378697

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"9279-1"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Respiratory rate"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#9279-1 for language(s) 'no-NO'. The display is 'Respiratory rate' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"9279-1","display":"Respiratory rate"},{"system":"http://snomed.info/sct","code":"271625008","display":"Rate of spontaneous respiration (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#9279-1 for language(s) 'no-NO'. The display is 'Respiratory rate' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#271625008 ('Rate of spontaneous respiration (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#9279-1 (\"Respiratory rate\"), http://snomed.info/sct#271625008 (\"Rate of spontaneous respiration (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#9279-1\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"9279-1\" found in http://loinc.org|2.82\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#271625008\""}]}

#25

POST https://tx.fhir.org/r4/ValueSet/$validate-code? HTTP/1.0
Accept: application/fhir+json; fhirVersion=4.0
Content-Type: application/fhir+json; fhirVersion=4.0;charset=UTF-8
User-Agent: fhir/publisher

{"resourceType":"Parameters","parameter":[{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"9279-1","display":"Respiratory rate"},{"system":"http://snomed.info/sct","code":"271625008","display":"Rate of spontaneous respiration (observable entity)"}]}},{"name":"displayLanguage","valueString":"no-NO"},{"name":"default-to-latest-version","valueBoolean":true},{"name":"valueSet","resource":{"resourceType":"ValueSet","id":"observation-vitalsignresult","meta":{"lastUpdated":"2019-11-01T09:29:23.356+11:00","profile":["http://hl7.org/fhir/StructureDefinition/shareablevalueset"]},"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/structuredefinition-wg","valueCode":"oo"}],"url":"http://hl7.org/fhir/ValueSet/observation-vitalsignresult","identifier":[{"system":"urn:ietf:rfc:3986","value":"urn:oid:2.16.840.1.113883.3.88.12.80.62"}],"version":"4.0.1","name":"VitalSigns","title":"Vital Signs","status":"active","experimental":false,"date":"2019-11-01T09:29:23+11:00","publisher":"FHIR project team","contact":[{"telecom":[{"system":"url","value":"http://hl7.org/fhir"}]}],"description":"This value set indicates the allowed vital sign result types.   The LOINC code for Vitals Signs panel (85353-1) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure panel (85354-9) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).","copyright":"This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use","compose":{"include":[{"system":"http://loinc.org","concept":[{"code":"85353-1"},{"code":"9279-1"},{"code":"8867-4"},{"code":"2708-6"},{"code":"8310-5"},{"code":"8302-2"},{"code":"9843-4"},{"code":"29463-7"},{"code":"39156-5"},{"code":"85354-9"},{"code":"8480-6"},{"code":"8462-4"},{"code":"8478-0"}]}]}}},{"name":"system-version","valueUri":"http://snomed.info/sct|http://snomed.info/sct/51000202101"},{"name":"diagnostics","valueBoolean":true}]}
200
access-control-allow-credentials:true
access-control-allow-headers:DNT,User-Agent,X-Requested-With,If-Modified-Since,Cache-Control,Content-Type,Range,Authorization
access-control-allow-methods:GET, POST, PUT, DELETE, OPTIONS
access-control-allow-origin:*
connection:keep-alive
content-length:4303
content-type:application/fhir+json; charset=utf-8
date:Fri, 26 Jun 2026 06:48:30 GMT
etag:W/"10cf-UwkzAQPVee1C6ysO3xyxhAR3uwA"
server:nginx
vary:Origin
x-powered-by:Express
x-request-id:tx-1378699

{"resourceType":"Parameters","parameter":[{"name":"result","valueBoolean":false},{"name":"system","valueUri":"http://loinc.org"},{"name":"x-caused-by-unknown-system","valueCanonical":"http://snomed.info/sct"},{"name":"code","valueCode":"9279-1"},{"name":"version","valueString":"2.82"},{"name":"display","valueString":"Respiratory rate"},{"name":"message","valueString":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated; There are no valid display names found for the code http://loinc.org#9279-1 for language(s) 'no-NO'. The display is 'Respiratory rate' which is a valid display for the default language"},{"name":"codeableConcept","valueCodeableConcept":{"coding":[{"system":"http://loinc.org","code":"9279-1","display":"Respiratory rate"},{"system":"http://snomed.info/sct","code":"271625008","display":"Rate of spontaneous respiration (observable entity)"}]}},{"name":"issues","resource":{"resourceType":"OperationOutcome","issue":[{"severity":"information","code":"invalid","details":{"text":"There are no valid display names found for the code http://loinc.org#9279-1 for language(s) 'no-NO'. The display is 'Respiratory rate' which is a valid display for the default language","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"invalid-display"}]},"expression":["CodeableConcept.coding[0].display"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"NO_VALID_DISPLAY_FOUND_NONE_FOR_LANG_OK"}]},{"severity":"information","code":"code-invalid","details":{"text":"The provided code 'http://snomed.info/sct#271625008 ('Rate of spontaneous respiration (observable entity)')' was not found in the value set 'http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1'","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"this-code-not-in-vs"}]},"expression":["CodeableConcept.coding[1].code"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"None_of_the_provided_codes_are_in_the_value_set_one"}]},{"severity":"error","code":"not-found","details":{"text":"A definition for CodeSystem 'http://snomed.info/sct' could not be found, so the code cannot be validated","coding":[{"system":"http://hl7.org/fhir/tools/CodeSystem/tx-issue-type","code":"not-found"}]},"expression":["CodeableConcept.coding[1].system"],"extension":[{"url":"http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id","valueString":"UNKNOWN_CODESYSTEM"}]}]}},{"name":"diagnostics","valueString":"0ms tx-op\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Analysing http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1 for validation purposes\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Parameters: disp-lang=no-NO, generate-narrative, default-to-latest\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Version Rules: default:http://snomed.info/sct#http://snomed.info/sct/51000202101\n0ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Prepare include[0]: \"(http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0)\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: \"http://loinc.org|2.82\"\n1ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Validate \"[http://loinc.org#9279-1 (\"Respiratory rate\"), http://snomed.info/sct#271625008 (\"Rate of spontaneous respiration (observable entity)\")]\"\n2ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://loinc.org#9279-1\"\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: CodeSystem found: http://loinc.org|2.82 for http://loinc.org\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: check code in (http://loinc.org)(85353-1,9279-1,8867-4,2708-6,8310-5,8302-2,9843-4,29463-7,39156-5,85354-9,8480-6,8462-4,8478-0) at CodeableConcept.coding[0]\n3ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Code \"9279-1\" found in http://loinc.org|2.82\n4ms http://hl7.org/fhir/ValueSet/observation-vitalsignresult|4.0.1: Check \"http://snomed.info/sct#271625008\""}]}