0.3.3 - ci-build Norway flag

VkpObservation - Local Development build (v0.3.3) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Resource Profile: VkpObservationBloodpressure - Detailed Descriptions

Draft as of 2022-02-10

Definitions for the vkp-Observation-Bloodpressure resource profile.

Guidance on how to interpret the contents of this table can be foundhere

0. Observation
ShortFHIR Blood Pressure Profile VKP
2. Observation.code
4. Observation.code.coding
Control1..?
6. Observation.code.coding:BPSCTCode
Slice NameBPSCTCode
Control0..*
Must Supporttrue
8. Observation.code.coding:BPSCTCode.system
Control1..?
Pattern Valuehttp://snomed.info/sct
10. Observation.code.coding:BPSCTCode.code
Control1..?
Pattern Value75367002
12. Observation.subject
Definition

Reference to the practitioner that performed the observation, identified by Norwegian national id number (Fødselsnummer or DNR).

A link to a resource representing the person or the group to whom the medication will be given.

VKP always references a Practitioner Resource using a norwegian national id number (Fødselsnummer or DNR) in a logical identifier in the practitioner.identifier element. The Name of the practitioner should be given in the performer.display element.

Example:

"performer":{
   "identifier":{
      "system":"urn:oid:2.16.578.1.12.4.1.4.1",
      "value":"05073500186"
     },
     "display":"Ærlend Sørgård"
}
TypeReference(Patient, no-basis-Patient)
14. Observation.subject.identifier
NoteThis is a business identifier, not a resource identifier (see discussion)
Must Supporttrue
16. Observation.subject.identifier.system
BindingThe codes SHALL be taken from VKP Subject Identifier systems ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/vkp-subject-identifiers.valueset)
Must Supporttrue
18. Observation.subject.identifier.value
Must Supporttrue
20. Observation.subject.display
Must Supporttrue
22. Observation.performer
TypeReference(Practitioner, no-basis-Practitioner)
Must Supporttrue
Must Support TypesNo must-support rules about the choice of types/profiles
24. Observation.performer.identifier
NoteThis is a business identifier, not a resource identifier (see discussion)
Must Supporttrue
26. Observation.performer.identifier.system
BindingThe codes SHALL be taken from VKP Performer Identifier systems ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/vkp-performer-identifiers.valueset)
Must Supporttrue
28. Observation.performer.identifier.value
Must Supporttrue
30. Observation.performer.display
Must Supporttrue
32. Observation.bodySite
ShortSimple body site where blood pressure was measured.
Comments

Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component.

BindingThe codes SHALL be taken from NoDomainVitalSignsBloodpressureBodySite-ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/NoDomainVitalSignsBloodpressureBodySiteValueSet)
34. Observation.bodySite.coding
BindingThe codes SHALL be taken from NoDomainVitalSignsBloodpressureBodySite-ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/NoDomainVitalSignsBloodpressureBodySiteValueSet)
36. Observation.bodySite.coding.system
Fixed Valuehttp://snomed.info/sct
38. Observation.bodySite.coding.code
BindingThe codes SHALL be taken from NoDomainVitalSignsBloodpressureBodySite-ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/NoDomainVitalSignsBloodpressureBodySiteValueSet)
40. Observation.method
ShortMethod of measurement of blood pressure.
BindingThe codes SHALL be taken from NoDomainVitalSignsBloodPressureMeasurementMethod-ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/NoDomainVitalSignsBloodPressureMeasurementMethodValueSet)
42. Observation.method.coding
BindingThe codes SHALL be taken from NoDomainVitalSignsBloodPressureMeasurementMethod-ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/NoDomainVitalSignsBloodPressureMeasurementMethodValueSet)
44. Observation.method.coding.system
Fixed Valuehttp://snomed.info/sct
46. Observation.method.coding.code
BindingThe codes SHALL be taken from NoDomainVitalSignsBloodPressureMeasurementMethod-ValueSet
(required to http://hl7.no/fhir/vkpobservation/ValueSet/NoDomainVitalSignsBloodPressureMeasurementMethodValueSet)
48. Observation.component:SystolicBP
Slice NameSystolicBP
50. Observation.component:SystolicBP.code
52. Observation.component:SystolicBP.code.coding
Control1..?
54. Observation.component:SystolicBP.code.coding:SBPSCTCode
Slice NameSBPSCTCode
ShortSystolic Blood Pressure SNOMED CT code
Control0..*
Must Supporttrue
56. Observation.component:SystolicBP.code.coding:SBPSCTCode.system
Control1..?
Must Supporttrue
Fixed Valuehttp://snomed.info/sct
58. Observation.component:SystolicBP.code.coding:SBPSCTCode.code
Control1..?
Must Supporttrue
Fixed Value271649006
60. Observation.component:DiastolicBP
Slice NameDiastolicBP
62. Observation.component:DiastolicBP.code
64. Observation.component:DiastolicBP.code.coding
Control1..?
66. Observation.component:DiastolicBP.code.coding:DBPSCTCode
Slice NameDBPSCTCode
ShortDiastolic Blood Pressure SNOMED CT code
Control0..*
Must Supporttrue
68. Observation.component:DiastolicBP.code.coding:DBPSCTCode.system
Control1..?
Must Supporttrue
Fixed Valuehttp://snomed.info/sct
70. Observation.component:DiastolicBP.code.coding:DBPSCTCode.code
Control1..?
Must Supporttrue
Fixed Value271650006